CPR Medical Devices, Inc. CPR Medical Devices, Inc.
CPR Medical Devices, Inc.
CPR Medical Devices Inc. address
E-mail CPR Medical Devices Inc.
 
Menu Tools: Open All  Close All  Locate  Move Previous  Move Next 

Home
Oxylator® Product Series
Overview
Oxylator® EM-100
Introduction
Brochure (PDF)
Operating Manual (PDF)
Algorithms and Charts
Components



Disassembly for Cleaning



Comparison of Features among Ventilation Devices


How to Use Effectively
Photographs
Publications


Patents, Approvals, and Clearances
Case Studies



St. Gallen Cantonal Hospital, Switzerland (PDF)



Hospital Princeps d'Espanya Bellvitge, Barcelona, Spain



Royal Victoria Hospital and McGill University, Montreal, QC, Canada



Montérégie's EMS System, Longueil, QC, Canada



NTV a Nederlands Tijdschrift Voor Anesthesi- medewerkers, Netherlands



Helicopter Emergency Medical Services, University Hospital Rotterdam, Netherlands



University of Massachussetts Medical Center, Worcester, MA, U.S.A.



Emergency Scientific Medical Center, Yerevan, Armenia


CPR Medical Devices Inc., Toronto, ON, Canada
Testimonials


Carter County Emergency & Rescue Squad, Inc., Elizabethton, TN, U.S.A.


University of Massachusetts Medical Center, Worcester, MA, U.S.A.


U.S. Department of Veteran Affairs, Dublin, GA, U.S.A.


Croft Rescue Squad, Spartanburg, SC, U.S.A.


Lenoir Memorial Hospital, Kinston, NC, U.S.A.


Dunn Rescue Squad, Inc., Dunn, NC, U.S.A.

Jefferson County EMS, Dandridge, TN, U.S.A.
Oxylator® FR-300
Introduction
Brochure (PDF)
Operating Manual (PDF)
Photographs
Publications


Patents, Approvals, and Clearances
Case Studies


St. Elisabeth Hospital, Tilburg, NL

University of Massachussetts Medical School, Worcester, MA, U.S.A.
Oxylator® EMX
Introduction
Brochure (PDF)
Operating Manual (PDF)
Photographs
Publications

Patents, Approvals, and Clearances
Distributors
Demonstration Videos
Case Studies
Oxylator® EM-100


St. Gallen Cantonal Hospital, Switzerland (PDF)


Hospital Princeps d'Espanya Bellvitge, Barcelona, Spain


Royal Victoria Hospital and McGill University, Montreal, QC, Canada


Montérégie's EMS System, Longueil, QC, Canada


NTV a Nederlands Tijdschrift Voor Anesthesi- medewerkers, Netherlands


Helicopter Emergency Medical Services, University Hospital Rotterdam, Netherlands


University of Massachussetts Medical Center, Worcester, MA, U.S.A.


Emergency Scientific Medical Center, Yerevan, Armenia

CPR Medical Devices, Inc., Toronto, ON, Canada
Oxylator® FR-300

St. Elisabeth Hospital, Tilburg, NL
University of Massachussetts Medical School, Worcester, MA, U.S.A.
Testimonials
Oxylator® EM-100

Carter County Emergency & Rescue Squad, Inc., Elizabethton, TN, U.S.A.

University of Massachusetts Medical Center, Worcester, MA, U.S.A.

U.S. Department of Veteran Affairs, Dublin, GA, U.S.A.

Croft Rescue Squad, Spartanburg, SC, U.S.A.

Lenoir Memorial Hospital, Kinston, NC, U.S.A.

Dunn Rescue Squad, Inc., Dunn, NC, U.S.A.
Jefferson County EMS, Dandridge, TN, U.S.A.
Distributors
Brochures
Oxylator® EM-100 (PDF)
Oxylator® FR-300 (PDF)
Oxylator® EMX (PDF)
Operating Manuals
Oxylator® EM-100 (PDF)
Oxylator® FR-300 (PDF)
Oxylator® EMX (PDF)
Publications
Oxylator® EM-100
Oxylator® FR-300
Oxylator® EMX
Demonstration Videos
News and Newsworthy

Helicopter Emergency Medical Services, University Hospital Rotterdam, Netherlands
REA 2000, Ostschweizer Bildungsaustellung, St. Gallen, Switzerland
Downloads
Brochures
Operating Manuals
Publications
Demonstration Videos
FAQs
Acknowledgments
Site Map
Contact

Features
Oxylator® outperforms bag-valve, in the European Journal of Anaesthesiology Oxylators® reviewed in the Journal of Emergency Medical Services
Oxylator® bests bag-valve in peer-review studies Oxylators® reviewed in JEMS magazine

Efficacy of Mask Ventillation Using the Oxylator EM-100™
in Manual Mode


Daniel A. Chartrand MD PhD, Denis St-Laurent RRT, and Gordon S. Fox MD FRCPC
Departments of Anesthesia, Royal Victoria Hospital and McGill University, Montreal, Canada.


INTRODUCTION

The Oxylator EM-100™ (CPR Medical Devices) has recently been cleared (FDA, HPB and TUV) as a ventilatory device for use during resuscitation. This manually-triggered constant-flow generator delivers pure oxygen when the operator depresses the oxygen-release button. In the manual mode, the operator is instructed to use a 2-second inspiratory time (TI) in order to produce a tidal volume (VT) which follows the JAMA recommendations (1). The pressure-relief safety valve must initially be set at 25 H2O if the operator believes that a higher peak inspiratory pressure is necessary to deliver an appropriate VT (TI of 2 seconds for adults) to a specific patient.

At the Royal Victoria Hospital (Montreal, Canada) two anesthesiologists have used the Oxylator™ EM-100 extensively for more than two years. This study was designed to evaluate if other health professionals with no previous experience with this device could perform adequate mask ventillation when using it in the manual mode. A secondary objective of this study was to assess the effect of training in these health professionals.

METHODS

Following approval by the Hospital Ethics Comittee, an informed consent was obtained from 40 healthy patients (ASA I or II). These patients had normal upper airways and were at no increased risk for regurgitation. A first group of twenty volunteers were ventilated by two anesthesiologists (MD:10 patients each) having more than two years of experience with the Oxylator™ EM-100. A second group of twenty patients were ventilated by five respiratory technicians (RRT:4 patients each), with no previous experience with the Oxylator™ EM-100.

While pre-oxygenating the patient prior to scheduled surgery, anesthesia was induced with vecuronium 0.5 mg, fentanyl 5 µ/kg, thiopental 5-7 mg/kg and succinylcholine 2 mg/kg. After obtaining complete muscle relaxation, mask ventilation with 100% oxygen was provided with the Oxylator™ EM-100, following the man-ufacturer's recommendations. The operator was instructed to press the oxygen-release button for two seconds (counting "a thousand and one, a thousand and two") and to release it for three seconds, and to repeat this breathing cycle for one minute. The pressure-relief setting was placed at 25 cmH2O and this setting was not modified for any of these 40 patients. After one minute of ventilation by mask, endotracheal intubation was (ETT 7.5 mm or 8.5 mm I.D.) was performed and another one-minute period of ventilation was provided by the same operator following the same instructions.

Oxygen flow was measured with a heated Fleisch #1 pneumotachometer positioned between the Oxylator™EM-100 and the mask (or ETT). The pressure drop across the pneumotachograph was measured by a differential piezoresistive pressure transducer (MicroSwitch 163PCO1D36, Honeywell). Airway pressure was measured with a piezoresistive transducer (Fujikura, FPM-02PG) inserted in a lateral tap of the connection between the pneumotachograph and the mask (or ETT). The signals from the two piezoresistive pressure transducers were amplified and then passed through 5-pole Bessel low-pass filters (902L, Frequency Devices) with their corner frequencies set at 30 Hz. Finally the signals were sampled
 
ABSTRACT

The Oxylator EM-100™ has recently been approved as a ventilatory device for use during resuscitation. This study compares the efficacy of mask ventilation provided by anaesthetists (MD) or respiratory technicians (RRT) using the EM-100. Twenty healthy volunteers were ventilated by two MD's with more than two years of experience with the EM-100™. A second group of twenty healthy volunteers was ventilated by 5 RRT's (four patients each) who never previously used the EM-100 . Immediately after induction of anaesthesia and also following endotracheal intubation (ETT), ventilation was accomplished by pressing the inspiratory flow button of the EM-100 for 2 seconds, then releasing it for the following three seconds, and repeating this breathing for one minute. Oxygen flow was measured with a heated Fleisch pneumotachometer and airway pressure with a piezoresistive transducer. Usin a mask or an ETT, MD's and RRT's provided ventilation which followed the JAMA recommendations for manually triggered devices. During mask ventilation, a peak airway pressure of 19.3± 3.5 cmH2O was required to achieve a 1-litre tidal volume (VT) and 13 patients required more than 20 cmH2O. The expired VT represented 93.2±7.7% of the VT obtained with a ETT for the MD's and 93.8±8.2% for the RRT's. Compared to the two MD's, RRT's only had a larger variability of TI and breathing frequency. During mask ventilation, mre than 93% of the inspired oxygen reached the lungs. Most of this difference is likely explained by leaks around the mask which were sometimes felt. Gastric inflation was not identified in any of these 40 patients.